Description
Lufft WS310 all-in-one compact weather station
The Lufft WS310 is ideal for measuring air temperature, relative humidity, solar irradiance, and air pressure. It is suitable for high-end applications where accuracy and build quality cannot be compromised.
For solar radiation measurements, the Lufft WS310 is equipped with a Kipp and Zonen CMP10 Class A pyranometer with thermopile sensors. The CMP10 is the benchmark pyranometer for solar farm irradiance monitoring systems.
The sensors are protected by a radiation shell for protection and to ensure measurement accuracy, making the WS310 compliant according to WMO guidelines.
The WS310 is suitable for all climates, with a temperature range of -50 to +60 °C. There are no moving parts and data processing is built-in. This makes the WS310 incredibly robust and easy to use.
As standard, we supply the Lufft WS310 with Modbus communications. However, it is possible to supply the sensor with SDI-12. Please let us know at the time of ordering which you would prefer.
As with all WS series compact weather sensors, it is possible to fit a temperature probe. The probe measures surface temperature and is ideal for the PV solar sector to measure the back of panel temperature.
General |
|
Dimensions | Ø approx. 150 mm, height approx. 332 mm |
Weight | Approx 1.5kg |
Interface | RS485, 2 – wire, half-duplex |
Power supply | 11 to 32 VDC |
Power supply | 5 to 11 VDC (electronics with limited precision of measurements) |
Power supply | 24 VDC +/- 10% (heater) |
Power consumption | 40 VA (heater) |
Operating temperature | -50 to 60 °C |
Operating rel. humidity | 0 to 100 % RH |
Cable length | 10 m |
Protection level housing | IP66 |
Standards/Regulations | No information available |
Mast mounting | Suitable for mast diameter 60 – 76 mm |
Temperature |
|
Principle | NTC |
Measuring range | -40 to 80 °C |
Unit | °C |
Accuracy | ±0.2 °C (-20…50 °C), otherwise ±0.5 °C (>-30 °C) |
Relative humidity |
|
Principle | Capacitive |
Measuring range | 0 to 100 % RH |
Unit | % RH |
Accuracy | ±2 % RH |
Air pressure |
|
Principle | MEMS capacitive |
Measuring range | 300 to 1200 hPa |
Unit | hPa |
Accuracy | ±0.5 hPa (0 to 40 °C) |
Radiation (CM10 Pyranometer) |
|
Response time | < 5 s |
Zero offset A | < 7 W/m² |
Zero offset B | < 2 W/m² |
Directional error (at 1000 W/m²) | < 0.2 % |
Temperature dependence of sensitivity | < 1 % (-10 ºC…40 ºC) |
Spectral range | 285 to 2,800 nm |
Measuring range | 4000 W/m² |
WS Series Frequently asked questions.
How do I mount my WS sensors?
The sensor can be mounted directly onto a 60mm diameter pole. The sensors come with ‘U’ mounting brackets. A mounting arm (which can attach to 40-80mm diameter poles) can be supplied too.
Are other communications protocols possible?
Possible interfaces are RS485 with supported protocols UMB-Binary, UMB-ASCII, Modbus-RTU, Modbus-ASCII, XDR, and SDI-12.
What data logger is the WS310 compatible with?
The WS310 is compatible with many commercially available Met/HydroMet dataloggers and PLS systems thanks to an open communication protocol.
Optional Extras:
- External temperature probe (can be used as a back of module temperature sensor)
- Rain gauge Lufft WTB100